490-2500KW OEM support city gas fired burner with FIDA 8kv transformer

[Return Home] [Go Back]

490-2500KW OEM support city gas fired burner with FIDA 8kv transformer

Product Abstract:

Install RWF40 regulator in the control panel ,can run for proportional control,Air and gas mix in burner head,By adjusting the combustion air and burner, can get the best combustion parameters.


Product Description
490-2500KW YXG250P OEM support city gas fired burner with FIDA 8kv transformer
commercial gas burner parts,gas fired burner,gas burner parts
City gas burner with special blast pipe.
 
Burner features:
Two-stage progressive.
Mechanical cam.
Low NOx emissions.
Install RWF40 regulator in the control panel ,can run for proportional control
Air and gas mix in burner head
By adjusting the combustion air and burner, can get the best combustion parameters.
 
BURNER TECHNICAL DATAS
Model YXG250P
Operation Diesel/light oil/kerosene/Methane
Minimum Thermal Power (kW) 490
Maximum Thermal Power (kW) 2500
Min flow rate (Nm3/H) 50
Max flow rate (Nm³/H) 253
Electric power supply type AC
No. of Phases 3N
Power Supply Voltage (V) 380
Power Supply Frequency (Hz) 50/60
Fan Motor Power (kW) 7.5

BURNER CATALOGUE:

http://www.yx-industrialburner.com/upload/file/af12471b3a3cfa247d0a4c77b3fa129c.pdf

BURNER PARTS
Matching boiler(Ton) 3
Model YXG250P
Gas valve ZRDLE420(include safety valve)
DN65
/
Valve size 2"
DN65
/
Controller LFL1.322
Air switch GW3A6
Transforma FIDA 8KV
Servo motor SQN30
Remark /
Burner spare parts are all famous brand:
SIEMENS CONTROLLER
DUNGS VALVE
DANFOSS NOZZLE
SUNTEC OIL PUMP
BRAHMA/PARKER SOLENOID VALVE
FIDA TRANSFERMA
SIEMENS SERVOMOTOR
 
Technical Descriptions
-Gas burner compliant with European standard EN676. Mechanical operation at two progressive stages.
-Continuous modulation operation by installing P.I.D. controller in the control panel
-Modulation ratio 1:4.
-Regulating combustion air and blast-pipe.
-Combustion air intake with throttle damper. Air flow adjustment with mechanical cam.
-Fully closing air damper on shutdown to avoid loss of heat through the chimney.
-Maintenance facilitated by the possibility of removing the combustion head without having to remove the burner from the boiler.
-Sliding boiler coupling flange to adapt the blast-pipe to the various types of boilers.
-Easy maintenance thanks to the two-sides hinge which allows the removal of the combustion head without having to remove the burner from the boiler.
-CE version gas train is complete with butterfly valve, operation and safety valve with electromagnetic drive, valve tightness control, minimum pressure switch, pressure regulator and gas filter.
-Fail proof connectors for burner/gas train connection
-Gas train exit: high.
-Flame detection by ionisation electrode with connector for micro amp meter.
-Control panel with display diagram for working mode with indication lights .
-Electric control board in light alluminum alloy with IP55 protection rating
-7-pole socket for burner electric and thermostatic supply.
-4-pole socket for second stage control or for the connection of the PID electronic regulator.
-Electrical system with protection rating IP40
Technical Descriptions
-Gas burner compliant with European standard EN676. Mechanical operation at two progressive stages.
-Continuous modulation operation by installing P.I.D. controller in the control panel (to be ordered separately with modulation probe).
-Modulation ratio 1:4.
-Regulating combustion air and blast-pipe.
-Combustion air intake with throttle damper. Air flow adjustment with mechanical cam.
-Fully closing air damper on shutdown to avoid loss of heat through the chimney.
-Maintenance facilitated by the possibility of removing the combustion head without having to remove the burner from the boiler.
-Sliding boiler coupling flange to adapt the blast-pipe to the various types of boilers.
-Easy maintenance thanks to the two-sides hinge which allows the removal of the combustion head without having to remove the burner 
 
from the boiler.
-CE version gas train is complete with butterfly valve, operation and safety valve with electromagnetic drive, valve tightness control, minimum 
 
pressure switch, pressure regulator and gas filter.
-Fail proof connectors for burner/gas train connection
-Gas train exit: high.
-Flame detection by ionisation electrode with connector for micro amp meter.
-Control panel with display diagram for working mode with indication lights .
-Electric control board in light alluminum alloy with IP55 protection rating
-7-pole socket for burner electric and thermostatic supply.
-4-pole socket for second stage control or for the connection of the PID electronic regulator.
-Electrical system with protection rating IP40
Technical Descriptions
-Gas burner compliant with European standard EN676. Mechanical operation at two progressive stages.
-Continuous modulation operation by installing P.I.D. controller in the control panel (to be ordered separately with modulation probe).
-Modulation ratio 1:4.
-Regulating combustion air and blast-pipe.
-Combustion air intake with throttle damper. Air flow adjustment with mechanical cam.
-Fully closing air damper on shutdown to avoid loss of heat through the chimney.
-Maintenance facilitated by the possibility of removing the combustion head without having to remove the burner from the boiler.
-Sliding boiler coupling flange to adapt the blast-pipe to the various types of boilers.
-Easy maintenance thanks to the two-sides hinge which allows the removal of the combustion head without having to remove the burner 
 
from the boiler.
-CE version gas train is complete with butterfly valve, operation and safety valve with electromagnetic drive, valve tightness control, minimum 
 
pressure switch, pressure regulator and gas filter.
-Fail proof connectors for burner/gas train connection
-Gas train exit: high.
-Flame detection by ionisation electrode with connector for micro amp meter.
-Control panel with display diagram for working mode with indication lights .
-Electric control board in light alluminum alloy with IP55 protection rating
-7-pole socket for burner electric and thermostatic supply.
-4-pole socket for second stage control or for the connection of the PID electronic regulator.
-Electrical system with protection rating IP40
 
BURNER REAL PROJECTS:

Contact us now !